Mã lỗi C15 — Toshiba DP1830

Code: C15

Description: PFP upper drawer tray abnormality: The PFP upper drawer tray-up motor not rotating the PFP upper drawer tray not moving normally.
Remedy: Does the tray up? (Perform the output check the test mode: 04-278/280)
NO 1) Check if the connector of the tray-up motor is disconnected. 2) Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. 3) Check if the connector CN13 on the MAIN board is disconnected. 4) Check if the connector pins are disconnected and the harnesses are open circuited. 5) Check if the conductor patterns on the PFP board and MIAN board are short circuited or open circuited. 6) Replace the PFP board. 7) Replace the MAIN board.
YES the tray-up sensor working? (Perform the input check the test mode: 13-[04. SENSOR TEST])
NO 1) Check if the connector of the sensor is disconnected. 2) Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. 3) Check if the connector CN13 on the MAIN board is disconnected. 4) Check if the slit reaches the sensor. 5) Check if the connector pins are disconnected and the harnesses are open circuited. 6) Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 7) Replace the PFP board. 8) Replace the MAIN board.
YES 1) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 2) Replace the MAIN board.

← Xem tất cả mã lỗi Toshiba DP1830

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie