Mã lỗi C04 — Toshiba DP2120

Code: C04

Description: PFP motor abnormality: The PFP motor not rotating normally
Remedy: the PFP motor working? (Perform the output check the test mode: 04-109/159)
NO 1) Check the signal line connector CN503 the PFP motor disconnected. Check the power line connector CN502 the PFP motor disconnected. Check the connector CN246 the PFP board disconnected. Check the signal line connector CN241 the PFP board disconnected. Check the power line connector CN242 the PFP board disconnected. Check the connector CN13 the MAIN board disconnected. Check the connector pins are disconnected and the harnesses are open circuited. Check the conductor patterns the PFP motor board, PFP board and MAIN board are short circuited open circuited. Replace the PFP motor. 10)Replace the PFP board. 11)Replace the MAIN board.
YES the LED the PFP motor board lit without flickering?
NO 1) Check if the connector pins are disconnected and the harnesses are open circuited. 2) Check if the conductor patterns on the PFP motor board, PFP board and MAIN board are short circuited or open circuited. 3) Replace the PFP motor. 4) Replace the PFP board. 5) Replace the MAIN board.
YES 1) Check if the PLL lock signal CN246-8 output from the PFP board is always “L” level. 2) Check if the voltage supplied to the microcomputer input terminal IC5-17 is always “L” level. 3) Replace the PFP board. 4) Replace the MAIN board.

← Xem tất cả mã lỗi Toshiba DP2120

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie