Code: C01
Description: Main motor is abnormal
Remedy: Is the main motor working? NO 1. Check if the connector CN1 of the main motor is disconnected. 2. Check if the connector J313 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circutied. 4. Check if the conductor patterns on the main motor board and LGC board are short- or open-circuited. 5. Replace the main motor. 6. Replace the LGC board. YES Is the LED on the main motor board lit without flickering? NO 1. Check if the connector pins are disconnected and the harnesses are open-circuited. 2. Check if the conductor patterns on the main motor board and LGC board are short- or open-circuited. 3. Replace the main motor. 4. Replace the LGC board. YES 1. Check if the PLL lock signal J313-11 output from the LGC board is always level “L”? 2. Check if the voltage supplied to the microcomputer input terminal IC10-7 is always “L”? 3. Replace the LGC board.