Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CC4 — Toshiba DP3500

Code: CC4

Description: Swing motor is abnormal
Remedy: MJ-1012/1013 (Finishier section) [Procedure 1] Rotate the swing motor in reverse by hand. Does the swing guide move up and down? NO Fix the swing mechanism. YES Is the swing guide closed detection switch-2 (MS6) working normally? NO Replace the switch. YES Is the swing guide open sensor (PI18) working normally? NO Replace the sensor. YES Is the swing motor (M7) rotating in reverse at the fixed timing? NO Replace the motor. YES END [Procedure 2] Is the safety zone switch (MS3) working normally? NO Replace the switch. YES Is the safety zone switch (MS3) correctly pressed? NO Fix the mechanism. YES Is the swing guide closed detection switch-2 (MS6) working normally? NO Replace the switch. YES Is the swing guide closed detection switch-2 (MS6) correctly pressed? NO Fix the mechanism. YES Replace the finisher controller PC board. [Procedure 3] Is the swing motor clock sensor (PI20) working normally? NO Replace the sensor. YES Does the voltage between J11-6 and -7 on the finisher controller PC board become 24V when the swing motor starts rotating? NO Replace the finisher controller PC board. YES Is the wiring between the swing motor and finisher controller PC board correct? YES Correct the wiring. NO Replace the swing motor.

← Xem tất cả mã lỗi Toshiba DP3500