Mã lỗi E20 — Toshiba DP4500

Code: E20

Description: Paper fed from the upper cassette not reaching the registration sensor
Remedy: Open the jam access cover. Is there any paper in front of the registration sensor? YES Remove the paper. NO Is the registration sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[2]/[A]) NO 1. Check if the connector of the registration sensor is disconnected. 2. Check if the connector J313 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board is short- or open-circuited. 5. Replace the registration sensor. 6. Replace the LGC board. YES Is the upper cassette feed clutch working? (Perform the output check in the test mode: 03-201) NO 1. Check if the connector of the upper cassette feed clutch is disconnected. 2. Check if the connector J310 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open-circuited. 4. Check if the conductor pattern on the LGC board for short- or open-circuited. 5. Replace the upper cassette feed clutch. 6. Replace the LGC board. YES Check the upper cassette feed roller and separation roller. Replace them if they are worn out.