Remedy: (1) Check between the exit sensor and the reflection mirror for foreign objects, and the reflection mirror for dirt. (2) Check the harness between the exit sensor and the LGC board for breaks. (3) Check mainly IC4, IC5 and CN7 on the LGC board for breaks and short-circuits. (4) Replace the exit sensor. (5) Replace the LGC board. (6) Initialize the ADF EEPROM, and perform automatic sensor adjustment.