Code: CB2
Description: Delivery motor is abnormal
Remedy: [Procedure 1] Try rotating the exit motor by hand. Does it operate smoothly? No Correct the mechanical mechanism. Yes Is the exit motor clock sensor (PI10) normal? No Replace the sensor. Yes Is the voltage across J11-6 and -7 on the finisher controller board 24V when the exit motor operates? No Replace the finisher controller board. Yes Is the wiring from the motor up to the controller board normal? No Correct the wiring. Yes Replace the motor. [Procedure 2] Try turning the exit motor in the reverse by hand. Does the oscillation guide move up and down? No Correct the oscillation mechanism. Yes Is oscillation guide close detection switch 2 (MS6) normal? No Replace the microswitch. Yes Is the exit motor (M2) operating in reverse at the fixed timing? No Replace the motor. Yes Replace the finisher controller board. [Procedure 3] Try turning the exit motor in the reverse by hand. Does the oscillation guide move up and down? No Correct the oscillation mechanism. Yes Is oscillation guide open sensor (PI18) normal? No Replace the sensor. Yes Is the exit motor (M2) operating in reverse at the fixed timing? No Replace the motor. Yes Replace the finisher controller board. [Procedure 4] Is the safety area detection switch (MS3) normal? No Replace the switch. Yes Is the safety area detection switch (MS3) correctly pressed? No Correct the mechanical mechanism. Yes Is the oscillation guide close detection switch (MS6) normal? No Replace the switch. Yes Is the oscillation guide close detection switch (MS6) correctly pressed? No Correct the mechanical mechanism. Yes Replace the finisher controller board.