Code: CB3
Description: Tray lift motor is abnormal
Remedy: [Procedure 1] Is the tray home position sensor (PI8) normal? No Replace the sensor. Yes Is the tray elevator mechanism normal? No Correct the mechanism. Yes Is 24V DC being supplied to the tray elevator motor (M5) from the finisher controller during tray drive? No Replace the finisher controller board. Yes Is the wiring from the finisher controller board up to the tray elevator motor (M5) normal? No Correct the wiring. Yes Replace the tray elevator motor (M5). [Procedure 2] Is the tray arriving at the tray upper limit switch (MS5) position? Yes Lower the tray position. No Is the tray upper limit switch (MS5) normal? No Replace the switch. Yes Is the wiring from the finisher controller board up to the tray upper limit detection switch normal? No Correct the wiring. Yes Replace the finisher controller board. [Procedure 3] Is the tray rising? No Is power being supplied to the motor from the finisher controller board during tray elevation? No Replace the finisher controller board. Yes Is there a trouble on the tray elevation mechanism? No Replace the tray elevator motor (M5). Yes Correct the tray elevation mechanism. Yes Are tray elevation motor clock sensors 1/2 (PI19/9) normal? No Replace the sensor board. Yes Replace the finisher controller.