Mã lỗi C41 — Toshiba DP8110

Code: C41

Description: Abnormal thermistor or heater at the power ON
Remedy: 1. Check the thermistors (1) Check if the connectors are disconnected. (2) Check if the center and side thermistors (front, rear) are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center and side thermistors are open-circuited. 2. Check the IH control board and IH coil (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil is disconnected. (3) Check if the thermostat is blown. (4) Check if the connectors on the IH control board are disconnected (AC input connector and LGC I/F connectors J552 and J553). (5) Check if the IH control board or the switching power supply unit are abnormal. • Replace the IH control board. 3. Check the LGC board (1) Check if the connector J334 is disconnected. (2) Check if the conductor pattern on the LGC board is short- or open-circuited. (3) Replace the LGC board. 4. Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Enter “400” with the digital keys, then press the [START] key. (3) Change the current status counter value “1” or “2” to “0”, then press the [SET] key or [INTERRUPT] key (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the copier enters the normal standby state.

← Xem tất cả mã lỗi Toshiba DP8110

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie