Code: CA1
Description: Polygonal motor abnormality: The polygonal motor is not rotating normally
Remedy: Is the polygonal motor rotating?
NO 1) Check if the connector of the harness is disconnected between MAIN board (CN24) and the laser optical unit. 2) Check if the harness is open circuited and the connector pin is disconnected. 3) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 4) Replace the laser optical unit. 5) Replace the MAIN board.
YES 1) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 2) Replace the MAIN board.
NO 1) Check if the connector of the harness is disconnected between MAIN board (CN24) and the laser optical unit. 2) Check if the harness is open circuited and the connector pin is disconnected. 3) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 4) Replace the laser optical unit. 5) Replace the MAIN board.
YES 1) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 2) Replace the MAIN board.