Code: E87
Description: ADF open jam: ADF has opened during ADF operation.
Remedy: Is the ADF opened?
YES Remove the original, if any, and close the ADF.
NO Is the ADF opening/closing sensor adjusted within the specified range?
NO Adjust the ADF opening/closing sensor.
YES Is the ADF opening/closing sensor working? (Perform the input check: 03-[INTERRUPT]ON/[4]/[3])
NO 1) Check if the connector of the ADF opening/closing sensor is disconnected. 2) Check if the connector CN74 on the ADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the ADF board is short circuited or open circuited. 5) Replace the ADF opening/closing sensor. 6) Replace the ADF board.
YES Replace the ADF board.
YES Remove the original, if any, and close the ADF.
NO Is the ADF opening/closing sensor adjusted within the specified range?
NO Adjust the ADF opening/closing sensor.
YES Is the ADF opening/closing sensor working? (Perform the input check: 03-[INTERRUPT]ON/[4]/[3])
NO 1) Check if the connector of the ADF opening/closing sensor is disconnected. 2) Check if the connector CN74 on the ADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the ADF board is short circuited or open circuited. 5) Replace the ADF opening/closing sensor. 6) Replace the ADF board.
YES Replace the ADF board.