Mã lỗi E71 — Toshiba e-Studio 166

Code: E71

Description: Jam not reaching the original registration sensor: The original fed from the original feeding tray does not reach the original registration sensor.
Remedy: Are the pickup roller, feed roller and separation roller stained or worn out?
YES Clean the rollers or replace them.
NO Is the original excessively curled or folded?
YES Flatten and set it again.
NO Are the original registration sensor working? (Perform the input check: 03-[INTERRUPT]ON/[5]/[6])
NO 1) Check if the connectors of the original registration sensor are disconnected. 2) Check if the connector CN74 on the ADF board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor pattern on the ADF board is short circuited or open circuited. 5) Replace the original registration sensor. 6) Replace the ADF board.
YES Replace the ADF board.