Code: C41
Description: Thermistor or heater abnormality at power-ON: Abnormality of service call the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON.
Remedy: Check item: Thermistor • Connector check • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Harness check Heater • Connector check • Check if the heater is broken. • Check if the thermostat is blown. MAIN board • Board check • Connector check (CN17) • Harness check Switching regulator Connector check (J509 and J510)
Parts to be replaced: CIS unit MAIN board
Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while pressing the [Clear/Stop] button, then enter the setting mode. (2) Input “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [OK] (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Parts to be replaced: CIS unit MAIN board
Clear the status counter After repairing the matter which caused the error [C41], perform the following: (1) Turn ON the power while pressing the [Clear/Stop] button, then enter the setting mode. (2) Input “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [OK] (to cancel [C41]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.