Code: C43
Description: Thermistor abnormality during warming up or in ready status after abnormality judgment
Remedy: Check item: Thermistor • Connector check • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Harness check Heater • Connector check • Check if the heater is broken. • Check if the thermostat is blown. MAIN board • Board check • Connector check (CN17) • Harness check
Parts to be replaced: MAIN board
Clear the status counter After repairing the matter which caused the error [C43], perform the following: (1) Turn ON the power while pressing the [Clear/Stop] button, then enter the setting mode. (2) Input “400”, then press [START]. (3) Change the current status counter value “4” to “0”, then press [OK] (to cancel [C43]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Parts to be replaced: MAIN board
Clear the status counter After repairing the matter which caused the error [C43], perform the following: (1) Turn ON the power while pressing the [Clear/Stop] button, then enter the setting mode. (2) Input “400”, then press [START]. (3) Change the current status counter value “4” to “0”, then press [OK] (to cancel [C43]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.