Mã lỗi C44 — Toshiba e-Studio 18

Code: C44

Description: Heater abnormality after abnormality judgment: The temperature of the fuser roller has exceeded the range of control (in this case, the main switch turns OFF automatically) or does not even reach the range.
Remedy: Check item: Thermistor • Connector check • Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly. • Harness check Heater • Connector check • Check if the heater is broken. • Check if the thermostat is blown. MAIN board • Board check • Connector check (CN17) • Harness check
Parts to be replaced: MAIN board
Clear the status counter Change the current status counter value (setting mode: 400) “5”, “7” or “9” to “0” for [C44], taking the same procedure as that for [C41]. * The status counter value is as follows in the following cases. Change them to “0” respectively. • The error occurred during warming-up: “5” • The error occurred after the equipment has become ready: “7” • The temperature detected by the center thermistor is 230°C or higher: “9” • The temperature detected by the side thermistor is 230°C or higher: “9” • The temperature detected by the edge thermistor is 230°C or higher: “9” only during printing.

← Xem tất cả mã lỗi Toshiba e-Studio 18