Code: 906
Description: Magenta toner retract solenoid error (DSLM)
Remedy: 1 Turn printer off and remove I/O board shield. Disconnect DCN4 connector from I/O board. Measure resistance between cable pins 5 and 6. Is resistance between 162 and 198 ohms? Replace I/O board. Go to step 5. Go to step 2. 2 Remove items to expose toner retract solenoid. Check toner retract solenoid cable connection. Is cable properly connected? Go to step 3. Properly connect cable. Reassemble and retest printer. 3 Check toner retract solenoid cable and connecting cable for visible damage. Is either cable damaged? Replace damaged cable or toner retract solenoid. Reassemble and retest printer. Go to step 4. 4 Disconnect toner retract solenoid cable from cable that attaches to I/O board. Check cable continuity from DCN4 pins 5 and 6 to connector that attaches to toner retract solenoid. Ensure that pins are not shorted. Is cable okay? Replace toner retract solenoid. Reassemble and retest printer. Replace cable. Reassemble and retest printer. 5 Reassemble and retest printer. Does 906 error reappear? Turn printer off and replace engine controller board. Problem solved.