Mã lỗi C56 — Toshiba e-Studio 195

Code: C56

Description: PFC board I/F error: Communication error has occurredbetween the PFC board and the equipment.
Remedy: Check the connection. 1. Check if the connector CN113 on the MAIN board is disconnected. 2. Check if the connector CN112 on the switching regulator is disconnected. 3. Check if any of the connectors CN241 and CN242 on the PFC board is disconnected. 4. Check if the relay connector between the ADU board and the PFC board is disconnected. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFC board and the MAIN board are short circuited or open circuited. 7. Replace the PFC board. 8. Replace the MAIN board.