Code: E51
Description: Paper transport jam (ADU section) Jam not reaching the ADU sensor: The paper does not reach the ADU sensor after it is switchbacked in the exit section.
Remedy: 1 Open the ADU. Is there any paper in front of the ADU sensor? Yes Remove the paper. 2 No 2 Is the ADU sensor working? (Perform the input check in the test mode: 13-[04. SENSOR TEST]) Yes 3 No 1. Check if either of the connectors CN251 on the ADU board is disconnected. 2. Check if the connector CN13 on the MAIN board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the ADU board and MAIN board are short circuited or open circuited. 5. Replace the ADU board. 6. Replace the MAIN board. 3 Check the rollers in the ADU. Replace them if they are worn out.