Code: C160
Description: PFP lower drawer tray abnormality
Causes: Tray-up motor PFP board PFU board Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check: FS-03-278, 280) Yes 2 No • Check if the connector of the tray-up motor is disconnected. (J967, J961, CN244) • Check if any of the connectors CN241 and CN244 on the PFP board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and PFU board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: FS-03- [F1]ON/[5]/[A], FS-03- [F1]ON/[5]/[E]) Yes 3 No • Check if the connector of the sensor is disconnected. (CN246, J960, J965, J966, J970, J972) • Check if any of the connectors CN241, CN244 and CN246 on the PFP board is disconnected. • Check if the connector CN913 on the PFU board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and PFU board are short circuited or open circuited. 3 PFU board • Check if the conductor pattern on the PFU board is short circuited or open circuited.