Code: C180
Description: LCF tray-up motor abnormality
Causes: LCF tray-up motor LCF board PFU board LCF tray-up sensor LCF tray bottom sensor
Remedy: 1 Does the tray move? (Perform the output check: FS-03-271) Yes 2 No • Check if the connector of the LCF tray-up motor is disconnected. (CN5, CN50) • Check if any of the connectors CN100 and CN101 on the LCF board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and PFU board are short circuited or open circuited. 2 Are the LCF tray-up sensor and LCF tray bottom sensor working? (Perform the input check: FS-03-[F1]ON/[8]/[A], FS-03-[F1]ON/[8]/[E]) Yes 3 No • Check if the connectors of the sensors are disconnected. • Check if any of the connectors CN100 and CN101 on the LCF board is disconnected. • Check if the connector CN923 on the PFU board is disconnected. • Check if the slit reaches the sensors. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and PFU board are short circuited or open circuited. 3 PFU board • Check if the conductor pattern on the PFU board is short circuited or open circuited.