Code: C412
Description: heater lamp abnormality at power-ON
Causes: Power supply unit. Thermistor LGC board
Remedy: 1 Power voltage Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) 2 Thermistor • Check if the center, side and front thermistor are installed properly. • Check if the harnesses of the center, side and front thermistor are open circuited. • Check if the connectors of the center, side and front thermistor are disconnected (J752). 3 Power supply unit and fuser unit • Is the fuser unit installed correctly? • Check if the heater lamp is broken. • Check if the terminal of the heater lamp is attached securely. • Check if the center and side thermostat are blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN508). • Check if the power supply unit is abnormal. 4 LGC board • Check if the connectors CN342 and CN353 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. 5 Status counter After repairing the matter which caused the error [C411/ C412], perform the following: • Performs FS-08-2002. • Change the current status counter value “1“, “2“ or “4“ to “0”. • Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.