Mã lỗi C449, C450 — Toshiba e-Studio 2000AC

Code: C449, C450

Description: Heater lamp abnormality after abnormality judgment
Causes:
Remedy: 1,2,3,4. Check the thermopiles, Heater and LGC board Check the above components following the procedures. 1, 2,3 and 4 for [C411/C412]. 5 Clear the status counter Change the current status counter value (08-2002) “5”, “6”, “7”, “9”, “19”, “21”, “22”, “23”, “24”, “25”, “27”, “29”, “38”, “41”, “48” or “50” to “0” for [C44X], taking the same procedure as that for [C41X]. * The status counter value is as follows in the following cases. - The error occurred during warming-up: “5” or “6” The error occurred after the equipment has become ready: “7”. - The temperature detected by the center thermistor is 200°C or higher, the temperature detected by the side thermistor is 200°C or higher or the temperature detected by the front thermistor is 230°C or higher: “9”, “19”, “22”, “23”, “25”, “27” or “29” - The error occurred during printing: “24” or “25”. - The error occurred during energy saving: “27”. - A paper jam occurred: “29”.

← Xem tất cả mã lỗi Toshiba e-Studio 2000AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin