Code: C4B0
Description: IGBT overheating abnormality
Causes: LGC board
Remedy: LGC board • Check if the conductor pattern on the board is short circuited or open circuited. • Check if EEPROM is mounted. Status counter 1. Performs FS-08-2002. 2. Reset the displayed current status counter value “3”, “8”, “10”, “11”, “12”, “13”, “14”, “15”, “16”, “17”, “18”, “20”, “21”, “26”, “28”, “30”, “31”, “32”, “33”, “34”, “35”, “36”, “37”, “39”, “40”, “42”, “43”, “44”, “45”, “46”, “47”, “49”, “51”, “52”, “53”, “54”, “55”, “56”, “57”, “58”, “59”, “60”, “61”, “62” or “63” to “0”. 3. Turn the power OFF and then back ON. Make sure that the equipment enters the normal status.