Causes: Side thermistor front thermistor LGC board Heater lamp Power supply unit
Remedy: Thermistor ¡E Check the gap between the side thermistor and the fuser roller. ƒt P. 6-85 "6.12.1 Adjustment of the non-contact thermistor Gap" ¡E Check that the front thermistor is installed properly. ¡E Connector check ¡E Check if the harnesses of the center, side and front thermistor are open circuited. LGC board ¡E Connector check (CN342, J752) ¡E Check if the conductor pattern on the LGC board is open circuited or short circuited. Power supply unit and fuser unit • Is the fuser unit installed correctly? • Check if the heater lamp is broken. • Check if the terminal of the heater lamp is attached securely. • Check if the center and side thermostat are blown • Check if the drawer connector is damaged or its connection is detected. • Check if the connectors of the power supply unit are disconnected (CN504, CN508). • Check if the power supply unit is abnormal.