Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi CE70 — Toshiba e-Studio 2000AC

Code: CE70

Description: Drum drive switching abnormality: The drum switching detection sensor (S11) is not turned ON after the drum motor was rotated for a specified period of time.
Causes: Drum switching motor (M3) Drum switching detection sensor (S11) LGC board
Remedy: 1 Is the drum switching motor (M3) operating properly? (Perform the output check: FS-03-240) Yes 7 No 2 2 Drum switching motor (M3) Check the connector (J803) of the motor. 3 Drum switching detection sensor (S11) Sensor check 4 LGC board • Connector check (CN367) • Board check 5 Is the drum TBU drive unit [1] installed properly? P. 8-229 "Fig.8-3" Install the drum TBU drive unit [1] properly. P. 8-229 "Fig.8-3" 6 Check that there is no friction or abnormality by pushing the protrusion [2] of the drive switching cam and the one [3] for the developer/paper feeding drive switching cam while the drum TBU drive unit [1] is removed. P. 8-229 "Fig.8-3" • If there is any foreign matter in the unit, remove it. • If the slide area spring [4] in the unit is deformed or is not attached properly, correct it. • Apply grease (Molykote EM-30L) to the slide area of the switching cam [5]. P. 8-229 "Fig.8-4" P. 8-229 "Fig.8-4" 7 Is the drum switching detection sensor (S11) working? (Perform the input check: FS-03-[ALL]OFF/ [8]/[G] (Highlighted in the black mode)) Yes 10 No 8 8 Drum switching detection sensor (S11) • Sensor, connector, joint connector check • Check if there is any foreign matter such as grease in the detection area of the drum switching detection sensor. 9 LGC board • Connector check (CN367) • Board check 10 Is the drum switching motor assembled in the drum drive unit able to be rotated smoothly by hand? Yes 12 No 11 11 Drum switching motor (M3) • While reinstalling the drum switching motor, push it so that its gear will slightly move away from the engaging gear. • Check the bracket in which the drum switching motor is installed. If it is deformed, replace it. 12 Is the drum switching guide able to be moved smoothly by hand after the drum switching motor has been removed? Yes 14 No 13 13 Drum switching motor (M3) Check if the slide area (guide, plate) of the drum switching guide is deformed or any foreign matter is attached to it. (Replace it if there is.) 14 LGC board Board check

← Xem tất cả mã lỗi Toshiba e-Studio 2000AC

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie