Code: E210
Description: PFU drawer transport jam (Paper not reaching the registration sensor): The paper does not reach the registration sensor after it has passed the PFU transport sensor.
Causes: Registration roller MAIN board High-speed/low-speed transport clutches Feed roller
Remedy: 1 Open the Automatic duplexing unit. Is there paper in front of the registration sensor? Yes Remove the paper. No 2 2 Is the registration sensor working? (Perform the input check in the test mode: 03-[A]/ [A]) Yes 3 No • Check if the connector of the registration sensor is disconnected. • Check if the connector CN22 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the registration sensor. • Replace the MAIN board. 3 Are the (high-speed/lowspeed) clutches working? (Perform the output check in the test mode: 03-203, 205) Yes 4 No • Check if the connectors of the (high-speed/ low-speed) transport clutches are disconnected. • Check if the connector CN27 on the MAIN board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the MAIN board is short circuited or open circuited. • Replace the (high-speed/low-speed) transport clutches. • Replace the MAIN board. 4 Feed roller Separation roller Pickup roller Transfer roller • Check the condition of the feed roller, separation roller and pickup roller of each paper source, and replace them if they are worn out. • Check the transport roller. Replace it if it is worn out.