Description: Bridge unit open jam: The bridge unit has opened during printing.
Causes: The bridge unit opening/closing switch LGC board
Remedy: 1 Is the bridge unit open? Yes Remove the paper if there is any, then close the unit. No 2 2 Is the bridge unit opening/ closing switch working? (Perform the input check in the test mode: FS-03-[ALL]OFF/[7]/[B]) Yes 3 No • Check if the connector of the bridge unit opening/closing switch is disconnected. • Check if the connector CN311 on the LGC board is disconnected. • Check if the connector pins are disconnected and the harnesses are open circuited. • Check if the conductor pattern on the LGC board is short circuited or open circuited. • Replace the bridge unit opening/closing switch. • Replace the LGC board. 3 Replacing board • Replace the LGC board.