Mã lỗi C451 — Toshiba e-Studio 2020c

Code: C451

Description: Abnormal temperature difference between the center thermopile and the edge thermistor
(Heater lamp abnormality after abnormality judgment)
Causes: Power supply unit Thermopile LGC board
Remedy: Power supply and fuser unit • Check if the fuser unit is installed properly. • Check if foreign matter or paper in the fuser unit is plugging up the monitoring opening of the thermopile. • Check if there is any stain on sensor area of the fuser belt thermopile. • Check if the heater lamp is open circuited. • Check if the connector of the heater lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply unit (power supply unit AC output connector CN408, CN409 and LGC/IF connector CN404, CN405) are disconnected. • Check if the power supply unit is broken. Thermopile • Check if foreign matter is plugging up the thermopile. • Check if the thermopile is installed properly. • Check if the harnesses are open circuited. LGC board • Check if the connectors CN333, CN345 and CN361 are disconnected. • Check if the conductor pattern on the LGC board is short circuited or open circuited. Status counter 1. Turn the power ON while [0] and [8] are pressed simultaneously. 2. Key in “2002”, then press the [START] button. 3. Reset the displayed current status counter value "38", "39", "41", "42", "48", "49", "50" or "51" to "0", then press [OK] or [INTERRUPT]. (The error C451 or C452 is cleared.) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal status

← Xem tất cả mã lỗi Toshiba e-Studio 2020c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie