Mã lỗi CC90 — Toshiba e-Studio 202L

Code: CC90

Description: Upper stack tray lift motor abnormality: The upper stack tray lift motor is not rotating or the upper stack tray is not moving normally. [MJ-1022]
Remedy: MJ-1022 Is the wiring between the finisher controller PC board and upper stack tray lift motor (M5) correct? NO Correct the wiring. YES Are the front and rear sides of the upper stack tray leveled? NO Level them. YES Is the upper stack tray lift motor clock sensor (S19) working properly? NO Replace the sensor. YES Is the stack tray paper height sensor (S10) working properly? NO Replace the sensor. YES Are the upper stack tray upper limit sensor (S25), upper stack tray full sensor (S22) and stack processing safety switch (S26) working properly? NO Replace the sensor or sensor controller PC board. YES Does the voltage between the pins J14-1 pin and -2 pin on the finisher controller PC board become 24 V when the upper stack tray lift motor starts rotating? NO Replace the finisher controller PC board. YES Check the wiring between the upper stack tray lift motor and finisher controller PC board. If there is no problem, replace the upper stack tray lift motor.