Mã lỗi CCB0 — Toshiba e-Studio 202L

Code: CCB0

Description: Rear jogging motor abnormality: Rear jogging motor is not rotating normally or the rear alignment plate is not moving normally. [MJ-1022] Alignment motor (rear) abnormality: The alignment motor (rear) is not rotating normally or the rear alignment plate is not moving normally. [MJ-1025]
Remedy: MJ-1022 (Rear jogging plate motor abnormality) Is the rear jogging plate home position sensor (S7) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and rear jogging motor (M4) correct? NO Correct the wiring. YES Has the rack run over the stopper of the roll? YES Fix it. NO 1) Replace the rear jogging motor. 2) Replace the finisher controller PC board. MJ-1025 (Alignment motor (rear) abnormality) Is the aligning plate home position sensor (rear) (PI5) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and aligning plate home position sensor (rear) correct? NO Correct the wiring. YES Is there any mechanical problem with the path of aligning plate? YES Fix the mechanism. NO Try replacing the alignment motor (rear) (M5). Is the problem corrected? YES End. NO Replace the finisher controller PC board.