Code: EA10
Description: Paper transport delay jam: The paper which has passed the bridge unit does not reach the inlet sensor. [MJ-1022/1025]
Remedy: MJ-1022 Is there any paper remaining on the transport path in the finisher or equipment? YES Remove the paper. NO Is the connector J10 on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and inlet sensor (S2) open circuited? YES Connect the connector securely. Replace the harness. NO Is the inlet sensor working normally? (Check the movement of the actuator.) ll NO 1) Connect the connector of the inlet sensor securely. 2) Attach the actuator securely if its shaft is out of place. 3) Replace the inlet sensor. YES Replace the finisher controller PC board. MJ-1025 Is there any paper remaining on the transport path in the finisher or equipment? YES Remove the paper. NO Is the connector CN16 (inlet sensor) on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and inlet sensor open-circuited? YES Connect the connector securely. Replace the harness. NO Is the inlet sensor working normally? (Check the movement of the actuator.) l NO 1) Attach the actuator securely if its shaft is out of place. 2) Replace the sensor. YES Replace the finisher controller PC board.