Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi EA40 — Toshiba e-Studio 202L

Code: EA40

Description: Door open jam: The finisher has been released from the equipment during printing. [MJ-1022/1025]
Remedy: MJ-1022 Is there any paper remaining on the transport path in the finisher or equipment? YES Remove the paper. NO Is the finisher connected with the equipment? NO Connect the finisher with the equipment. YES Is the connector J11 on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and joint sensor (S4) open circuited? YES Connect the connector securely. Replace the harness. NO Is the joint sensor working properly? l NO 1) Connect the connector of the joint sensor securely. 2) Replace the joint sensor. YES Replace the finisher controller PC board. MJ-1025 Is the finisher connected with the equipment? Are the upper cover and front door of the finisher closed? l YES 1) Connect the finisher with the equipment. 2) Close the cover and door of the finisher. NO Is any of the connectors CN4 (upper cover sensor and front door sensor) and CN8 (joint switch) on the finisher controller PC board disconnected? Is the harness connecting the finisher controller PC board and each sensor (upper cover sensor or front door sensor) open-circuited? Is the harness connecting the finisher controller PC board and joint switch (MS2) open-circuited? YES Connect the connector securely. Replace the harness. NO Are the joint switch, upper cover sensor and front door sensor working properly? NO 1) Attach the actuator securely if its shaft is out of place. 2) Replace the switch or sensor. YES Replace the finisher controller PC board.

← Xem tất cả mã lỗi Toshiba e-Studio 202L

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie