Code: L4 32
Description: Exhaust fan motor lock detection trouble. The error detection is started after 2 sec from starting rotation of the exhaust fan motor. 1) The continuous rotation state of 250ms is not detected for 1 sec after starting detection. 2) When the lock sensor (in the exhaust fan) detects the HIGH level (unstable) after detection the lock state (stable state).
Causes: Exhaust fan motor connector connection trouble Exhaust fan motor trouble MCU PWB trouble
Remedy: Exhaust fan motor connector connection check Exhaust fan motor replacement Replace the MCU PWB.