Mã lỗi CA20 — Toshiba e-Studio 2040c

Code: CA20

Description: H-Sync detection error: H-Sync signal detection PC board cannot detect laser beams.
Causes: Power supply unit Laser optical unit LGC board
Remedy: 1 LGC board • Check the connectors and harnesses between CN356 and LDR board. • Check the connectors and harnesses between CN355 and SNS board. • Connector check (J503, J505) 2 Front cover ADU Close the front cover and ADU if it is open. 3 Is the pin CN405-4 on the power supply unit +5V? Yes 4 No 5 4 Is the pin CN361-4 on the LGC board +5V? Yes 6 No 5 5 Power supply unit Check the connectors and harnesses between the power supply unit and LGC board. 6 LGC board Board check 7 Units with high-voltage • Check if the units with high-voltage (developer unit, transfer belt unit, 2nd transfer roller unit) are securely grounded. • Check if the bias supply joints of the units with high-voltage are securely connected or they are not stained. 8 Plate in the paper transport system Check if the plate in the paper transport system is securely grounded. 9 Equipment Check if the equipment is grounded. 10 Laser unit cooling fan • Check if the laser unit cooling fan is stopped. • Check if the suction area of the laser unit cooling fan is plugged up.