Code: E13
Description: Drawer misfeeding (Paper not reaching the registration sensor): The paper fed from the drawer does not reach the registration sensor.
Remedy: Open the transfer cover. there any paper front the registration sensor?
YES Remove the paper. Is the registration sensor working? (Perform the input check the test mode: 13-[04. SENSOR TEST])
NO 1) Check if the connector of the registration sensor is disconnected. 2) Check if the connector CN26 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 5) Replace the registration sensor. 6) Replace the MAIN board.
YES the pickup solenoid working? (Perform the output check the test mode: 04-201)
NO 1) Check if the connector of the pickup solenoid is disconnected. 2) Check if the connector CN26 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 5) Replace the pickup solenoid. 6) Replace the MAIN board.
YES Check the drawer pickup roller. Replace if is worn out.
YES Remove the paper. Is the registration sensor working? (Perform the input check the test mode: 13-[04. SENSOR TEST])
NO 1) Check if the connector of the registration sensor is disconnected. 2) Check if the connector CN26 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 5) Replace the registration sensor. 6) Replace the MAIN board.
YES the pickup solenoid working? (Perform the output check the test mode: 04-201)
NO 1) Check if the connector of the pickup solenoid is disconnected. 2) Check if the connector CN26 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 5) Replace the pickup solenoid. 6) Replace the MAIN board.
YES Check the drawer pickup roller. Replace if is worn out.