Code: CC31
Description: Transport motor abnormality: The transport motor is not rotating or the stack transport roller -1 and -2 is not rotating normally.
Causes: Transport motor (M2) Finisher controller PC board
Transport motor Finisher control PC board
Transport motor Finisher control PC board
Remedy: MJ-1101 Stack transport roller If there is mechanical problem when the stack transport roller -1 and -2 are rotated, fix the mechanism. Transport motor (M2) Check the connectors and harnesses between the transport motor (M2) and the finisher control PC board (CN5).
MJ-1106 Stack transport roller -1 Stack transport roller -2 Rotate the stack transport roller -1 and -2. Fix any mechanical problem. Transport motor Check if the connector (CN10) on the finisher controller PC board is disconnected from the transport motor (M7) and the harnesses are open circuited. Correct if so.
MJ-1106 Stack transport roller -1 Stack transport roller -2 Rotate the stack transport roller -1 and -2. Fix any mechanical problem. Transport motor Check if the connector (CN10) on the finisher controller PC board is disconnected from the transport motor (M7) and the harnesses are open circuited. Correct if so.