Mã lỗi CE71 — Toshiba e-Studio 2050c

Code: CE71

Description: Drum phase adjustment abnormality: Drum phase sensors (Color drum phase sensor (S43) and K drum phase sensor (S44)) are not turned ON after the drum motor was rotated for a specified period of time.
Causes: Drum motor (M10) Drum drive unit • Color drum phase sensor (S43) • K drum phase sensor (S44) LGC board
Remedy: 1 • Is the error cleared after the power is turned OFF and then back ON? • Is the drum motor (M10) operating properly? (Perform the output check: ON 03-101 / OFF 03-151.) * Check the operation after removing all process units (EPU (Y, M, C, K)). Yes 5 No 2 2 Drum motor (M10) Connector check 3 Drum drive unit Check if their drive gears are damaged or if they contact with the equipment. Correct if any. 4 LGC board • Connector check (CN332) • Board check 5 Rotate the drum of each EPU in the direction of the arrow once. (See the figure below.) If the rotation of the drum is extremely heavy or not smooth, check if the mechanism of the EPU is normal. Fig. 8-1 6 Rotate the drum with 03-101. Are the drum phase sensors (Color drum phase sensor (S43) and K drum phase sensor (S44)) are operating properly? (Perform the input check: Color 03-[ALL]OFF/[1]/[F] K 03-[ALL]OFF/[1]/[E].) Yes 9 No 7 7 Drum phase sensor • Check the connector of the drum phase sensors (S43, S44) and joint connectors • Check if there is any foreign matter such as grease in the detection area of the drum phase sensors (S43, S44). 8 LGC board • Connector check (CN332) • Board check 9 Drum drive unit Check if the drive gears are installed properly. (Check if the mark on each gear is aligned with the area of the punched mark on the frame.) 10 Actuator Check if the actuator is installed properly. 11 LGC board Board check
CE71 error can be prevented by setting the drum phase adjustment control OFF in the self-diagnostic code below. The setting value shall be returned after the recovery, otherwise color deviation increases. Drum phase adjustment control ON/OFF code 08-4766 0: Disabled 1: Enabled (Default)

← Xem tất cả mã lỗi Toshiba e-Studio 2050c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie