Description: Waste toner box mixing paddle locked: The mixing paddle in the waste toner box does not rotate.
Causes: Waste toner box Waste toner paddle motor (M6) Waste toner paddle motor lock detection sensor (S14) LGC board
Remedy: 1 Do the paddles in the waste toner box rotate? (Actually make them rotate.) Yes 2 No Replace the waste toner box. 2 Is the waste toner paddle motor (M6) rotating? (Perform the output check: 03-414) Yes 5 No 3 3 Waste toner paddle motor (M6) • Connector and relay connector check • Check if there is any damage or abnormality in the gears on the driving cascade of the waste toner paddle motor. 4 LGC board • Connector check (CN359) • Board check 5 Is the waste toner paddle motor lock detection sensor (S14) operating normally? (Perform output check: 03-[FAX] OFF/[1]/ [C]) * To judge an error, check if the sensor detects each status of normal display and highlighted display. Yes 7 No 6 6 Waste toner paddle motor lock detection sensor (S14) Connector and relay connector check 7 LGC board • Connector check (CN359) • Board check