Code: CB30
Description: Tray lift motor abnormality: The tray lift motor is not rotating normally or the delivery tray is not moving normally. [MJ-1025] Tray 1/Tray 2 shift motor abnormality: Tray 1/Tray 2 shift motor is not rotating or delivery tray is not moving normally. [MJ-1024] Movable tray shift motor abnormality: The movable tray shift motor is not rotating or the movable tray is not moving normally. [MJ-1101]
Remedy: MJ-1025 [Procedure 1] Is the paper surface sensor (PI9) working properly? NO Replace the sensor. YES Is the tray up/down mechanism working properly? NO Fix the mechanism. YES Is 24 VDC supplied from the finisher controller PC board to the shift motor as soon as the tray is driven? NO Replace the finisher controller PC board. YES Is the wiring between the finisher controller PC board and shift motor (M6) correct? YES Replace the shift motor. NO Correct the wiring. [Procedure 2] Is the tray as far as the shift upper limit sensor? YES Lower the position of the tray. NO Is the shift upper limit sensor (PI15) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and shift upper limit sensor (PI15) correct? YES Replace the finisher controller PC board. NO Correct the wiring. [Procedure 3] Does the tray go up? YES NO Is 24 VDC supplied from the finisher controller PCB to the shift motor as soon as the tray is driven? NO Replace the finisher controller PC board. YES Is there any problem with the tray up/down mechanism? YES Fix the lift mechanism. NO Replace the shift motor. Is the shift motor clock sensor (PI7) working properly? YES Replace the finisher controller PC boar NO Replace the sensor.
MJ-1024 Are the tray 1 shift area sensors 1-3 and tray 2 shift area sensors 1-3 normal? NO Replace the tray 1/2 shift area sensor boards. YES Are the wirings between the finisher controller PC board and the tray 1/2 shift motors (M37/ M38) correct? NO Correct the wirings. YES Is there any problem with the tray lift mechanism? NO Fix the lift mechanism. YES 1. Replace the tray 1/2 shift motors. 2. Replace the finisher controller PC board.
MJ-1101 Is there any mechanical problem when the movable tray is moved? ..YES Fix the mechanism. NO Is the harness between the movable tray shift motor (M7) and the finisher control PC board (CN8) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO Is there a disconnection of the connector, incorrect installation or breakage of the movable tray position A, B, and C sensors (S13, S14, and S15)? l ..YES • Replace the harness. • Reinstall the sensor correctly. • Replace the sensor. NO 1. Replace the movable tray shift motor (M7). 2. Replace the finisher control PC board.
MJ-1024 Are the tray 1 shift area sensors 1-3 and tray 2 shift area sensors 1-3 normal? NO Replace the tray 1/2 shift area sensor boards. YES Are the wirings between the finisher controller PC board and the tray 1/2 shift motors (M37/ M38) correct? NO Correct the wirings. YES Is there any problem with the tray lift mechanism? NO Fix the lift mechanism. YES 1. Replace the tray 1/2 shift motors. 2. Replace the finisher controller PC board.
MJ-1101 Is there any mechanical problem when the movable tray is moved? ..YES Fix the mechanism. NO Is the harness between the movable tray shift motor (M7) and the finisher control PC board (CN8) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO Is there a disconnection of the connector, incorrect installation or breakage of the movable tray position A, B, and C sensors (S13, S14, and S15)? l ..YES • Replace the harness. • Reinstall the sensor correctly. • Replace the sensor. NO 1. Replace the movable tray shift motor (M7). 2. Replace the finisher control PC board.