Description: Upper stack tray lift motor abnormality: The upper stack tray lift motor is not rotating or the upper stack tray is not moving normally. Tray shift motor abnormality: The tray shift motor is not rotating or the stack tray is not moving normally. [MJ- 1031]
Remedy: MJ-1031 Is the wiring between the finisher controller PC board and tray shift motor (M2) correct? NO Correct the wiring. YES Are the front and rear sides of the stack tray leveled? NO Level them. YES Is the tray clock sensor (SR9) working properly? NO Replace the sensor. YES Are the tray lower limit sensor (SR5), tray 500 sensor (SR4) and tray safety switch (SW2) working properly? NO Replace the sensor or sensor controller PC board. YES Does the voltage between the pins J114-1 and -2 on the finisher controller PC board become 24V when the tray shift motor starts rotating? NO Replace the finisher controller PC board. YES Check the wiring between the tray shift motor and finisher controller PC board. If there is no problem, replace the tray shift motor.