Code: CDE0
Description: Paddle motor abnormality: The paddle motor does not rotate properly. [MJ-1025]
Remedy: MJ-1025 Is the paddle home position sensor (PI2) working properly? NO Replace the sensor. YES Is the Swing guide home position sensor (PI3) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and Paddle motor (M2) correct? NO Correct the wiring. YES Try to rotate the paddle motor (M2) clockwise and counterclockwise by hand. Is there mechanical trapping in the rotation of the paddle or the up/down movement of the swing guide? YES Fix the mechanism. NO 1. Replace the paddle motor (M2) 2. Replace the finisher controller PC board.
the initial operation. MJ-1101 Is there any mechanical problem with the paddle is rotated? ..YES Fix the mechanism. NO Is the harness between the paddle motor (M8) and the finisher control PC board (CN6) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO 1. Replace the paddle motor (M8). 2. Replace the finisher control PC board.
the initial operation. MJ-1101 Is there any mechanical problem with the paddle is rotated? ..YES Fix the mechanism. NO Is the harness between the paddle motor (M8) and the finisher control PC board (CN6) disconnected or open circuited? l ..YES • Reconnect the connector securely. • Replace the harness. NO 1. Replace the paddle motor (M8). 2. Replace the finisher control PC board.