Code: CC54
Description: Hole punch registration sensor detection error: An abnormality occurs in the hole punch registration sensor. [MJ-1032/MJ-1033]
Causes:
Remedy: MJ-1032 Paper detection sensors (S24 and S25) abnormality Measure the voltage on pin CN6.8 on the hole punch control PC board (HP). Then check that the measured voltage is 3.0V or higher when not shielded and 1.2V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN4, CN6) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the sensors and the connectors, exchange the hole punch control PC board (HP).
MJ-1033 Trailing edge detection sensors (S39 and S40) abnormality Measure the voltage on TP48 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (B5-R/ST-R) Measure the voltage on TP47 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (A4-R/LT-R) Measure the voltage on TP46 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (B4/LG) Measure the voltage on TP45 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (A3/LD) Measure the voltage on TP44 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN4) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the sensors and the connectors, exchange the hole punch control PC board (HP).
MJ-1033 Trailing edge detection sensors (S39 and S40) abnormality Measure the voltage on TP48 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (B5-R/ST-R) Measure the voltage on TP47 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (A4-R/LT-R) Measure the voltage on TP46 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (B4/LG) Measure the voltage on TP45 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Horizontal registration detection sensors (S39 and S40) abnormality (A3/LD) Measure the voltage on TP44 on the hole punch control PC board (HP). Then check that the measured voltage is 2.5V or higher when not shielded and 1V or lower when shielded. If the voltage does not fall within the range mentioned, replace a couple of PC boards on either the light-receiving side or the light-emitting side. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Hole punch control PC board (HP): CN4) Hole punch control PC board (HP) abnormality If the error still occurs after replacing the sensors and the connectors, exchange the hole punch control PC board (HP).