Code: EA2E
Description: Paper transport remaining jam in the Finisher (subpath sensor): Paper is detected in the sub-path sensor when the power is turned ON or the cover is closed. [MJ-1032]
Causes: MJ-1032
Remedy: MJ-1032 Entrance path sensor (S19) abnormality Measure the voltage on TP86 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V±5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Middle path sensor (S7) abnormality Measure the voltage on TP84 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Sub-path sensor (S8) abnormality Measure the voltage on TP85 on the finisher control PC board (FIN). Then check that the measured voltage is 1V or lower when not shielded and within the range of 3.3V ± 5% when shielded. If the voltage does not fall within the range mentioned, replace the sensor. Faulty cables and connectors Check if the electrical continuity between the connector terminals is normal. If electricity is not conducted, replace the connector. (Finisher control PC board (FIN): CN6, CN22) Finisher control PC board (FIN) abnormality If the error still occurs after replacing the senso