Code: C29
Description: Exposure lamp disconnection detected
Remedy: Does the exposure lamp light? Y: 1. Check the CCD and SCM boards for any disconnected connector. 2. Check the shading correction plate of the original-width indicator unit if it is dusty. 3. Check the CCD board for any open- or short-circuited conductor pattern. 4. Check the SCM board for any open- or short-circuited conductor pattern. 5. Replace the SCM board. 6. Replace the lens unit. N: 1. Check if the lamp connector is disconnected. 2. Check the SCM board if any pin of connectors J7-1, -2 and -3 is disconnected or any harness is open- or short-circuited. 3. Check the SCM board for any open- or short-circuited conductor pattern. 4. Replace the SCM board. 5. Replace the inverter. 6. Replace the exposure lamp.