Remedy: Is the harness between the LGC board and the EPU drawer connector open-circuited? Is any harness inside the EPU or the auto-toner sensor harness open-circuited? Is the auto-toner sensor connector or the connector J120 on the LGC board disconnected? Y: Reconnect the connector. Replace the harness. N: 1. Replace the auto-toner sensor. 2. Replace the LGC board.