Code: F07
Description: Communications error between system-CPU and LGC-CPU
Remedy: Did the error occur immediately after updating the firmware? Y: Are the proper files saved in the PC? (In case of updating by PC) Are the type, attaching position and direction of the ROM correct? (In case of updating by download jig) N: After correcting, perform the firmware updating again. Y: Though the firmware updating was carried out correctly, error occurs.) N: Did the error occur during printing by the printer controller? Y: Turn OFF and ON the power of printer controller. N: 1. Check if the SYC board is securely connected to the MTH1 board. 2. Check if the IMC board is securely connected to the MTH1 board. 3. Check if the IMC board connector J182 is disconnected. 4. Check if the LGC board connector J113 is disconnected. 5. Check if the harness between the IMC and LGC boards is open-circuited. 6. Check the version of FROM on the SYS board. 7. Check the version of MROM on the LGC board. 8. Check the version of IMC-ROM on the IMC board. 9. Replace the SYS board. 10. Replace the IMC board. 11. Replace the LGC board.