Code: C01

Description: Main motor abnormality: The main motor not rotating normally.
Remedy: Is the main motor working? (Perform the output check the test mode: 04-101/151)
NO 1) Check if the connector CN1 of the main motor is disconnected. 2) Check if the connector CN16 on the MAIN board is disconnected. 3) Check if the connector pins are disconnected and the harnesses are open circuited. 4) Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 5) Replace the main motor. 6) Replace the MAIN board.
YES the LED the main motor board lit without flickering?
NO 1) Check if the connector pins are disconnected and the harnesses are open circuited. 2) Check if the conductor patterns on the main motor board and MAIN board are short circuited or open circuited. 3) Replace the main motor. 4) Replace the MAIN board.
YES 1) Check if the PLL lock signal CN305-B8 output from the MAIN board is always level “L”? 2) Check if the voltage supplied to the CPU input terminal IC24-12 is always “L”? 3) Replace the MAIN board.