Code: CB50
Description: Staple motor (staple/fold) abnormality: The staple motor is not rotating normally or the stapler is not moving normally. [MJ-1025]
Remedy: MJ-1025 [Procedure 1] Is the wiring between the finisher controller PC board and the staple/fold motor normal? NO Correct the wiring. YES Try to rotate the staple jam releasing dial. Is there mechanical trapping? YES Fix the mechanism. NO Try replacing the staple/fold motor (M7). Is the problem corrected? YES End. NO Replace the finisher controller PC board. [Procedure 2] Is the staple/fold motor clock sensor (PI14) working properly? NO Replace the sensor. YES Does the staple/fold motor operate at the appropriate timing? YES Replace the finisher controller PC board. NO Is the stapler unit drive mechanism working properly? NO Fix the mechanism. YES Try replacing the staple/fold motor (M7). Is the problem corrected? YES End. NO Replace the finisher controller PC board. [Procedure 3] Is the folding home position sensor (PI11) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and the staple/fold motor normal? NO Correct the wiring. YES Try to rotate the fold jam releasing dial. Is there mechanical trapping? YES Fix the mechanism. NO Try replacing the staple/fold motor (M7). Is the problem corrected? YES End. NO Replace the finisher controller PC board. [Procedure 4] Is the staple/fold motor clock sensor (PI14) working properly? NO Replace the sensor. YES Does the staple/fold motor operate at the appropriate timing? YES Replace the finisher controller PC board. NO Is the saddle stitch unit drive mechanism working properly? NO Fix the mechanism. YES Try replacing the staple/fold motor (M7). Is the problem corrected? YES End. NO Replace the finisher controller PC board.