Mã lỗi CC80 — Toshiba e-Studio 230

Code: CC80

Description: Front jogging motor abnormality: Front jogging motor is not rotating normally or the front alignment plate is not moving normally. [MJ-1022] Alignment motor (front) abnormality: The alignment motor (front) is not rotating normally or the front alignment plate is not moving normally. [MJ-1025]
Remedy: MJ-1022 (Front jogging plate motor abnormality) Is the front jogging plate home position sensor (S6) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and front jogging motor (M3) correct? NO Correct the wiring. YES Has the rack run over the stopper of the roll? YES Fix it. NO 1) Replace the front jogging motor. 2) Replace the finisher controller PC board. MJ-1025 (Alignment motor (front) abnormality) Is the aligning plate home position sensor (front) (PI4) working properly? NO Replace the sensor. YES Is the wiring between the finisher controller PC board and alignment motor (front) (M4) correct? NO Correct the wiring. YES Is there any mechanical problem with the path of aligning plate? YES Fix the mechanism. NO Try replacing the alignment motor (front) (M4). Is the problem corrected? YES End. NO Replace the finisher controller PC board.