Code: C160
Description: PFP lower drawer tray abnormality: The PFP lower drawer tray motor is not rotating or the PFP lower drawer tray is not moving normally.
Causes: PFP board MAIN board Tray-up motor Tray-up sensor
Remedy: 1 Does the tray go up? (Perform the output check in the test mode: 03-278/ 280) Yes 2 No 1. Check if the connector of the tray-up motor is disconnected. 2. Check if any of the connectors CN410, CN413 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 6. Replace the PFP board. 7. Replace the MAIN board. 2 Is the tray-up sensor working? (Perform the input check in the test mode: 03-[1]/ [G], 03-[2]/[E]) Yes 3 No 1. Check if the connector of the sensor is disconnected. 2. Check if any of the connectors CN410, CN414 and CN415 on the PFP board is disconnected. 3. Check if the connector CN26 on the MAIN board is disconnected. 4. Check if the slit reaches the sensor. 5. Check if the connector pins are disconnected and the harnesses are open circuited. 6. Check if the conductor patterns on the PFP board and MAIN board are short circuited or open circuited. 7. Replace the PFP board. 8. Replace the MAIN board. 3 MAIN board 1. Check if the conductor pattern on the MAIN board is short circuited or o